江蘇雙馬的柴油發電機組不僅在國內擁有眾多客戶,在國外的市場依舊火熱。今天小編就給各位中外的客官出一個中英版的柴油發電機使用注意事項。記得為江蘇雙馬打call哦。
檢查柴油機供油、潤滑、冷卻等系統各管路及接頭有無漏水、漏油現象;電氣線路無破皮等漏電隱患;接地線等電氣線路是否有連接松動;機組與基礎的連接是否牢固
Check the diesel's pipes and joints of oil supplying, lubricating and cooling system has no phenomenon of water or oil leakage; The hidden perils of creepage with electric lines broken;The electrical lines includes ground wire has no loose connections;The connection generator set and foundation is strong
環境溫度低于零度時,須在散熱器內添加一定比例的防凍液(具體要求參照柴油機隨機資料)
The ambient temperature is lower than zero, must add antifreeze in a certain proportion in the radiator (specific requirements refer to the diesel engine random data)
機組次起動或停用較長時間后再次啟動時,應先用手壓泵排盡燃油系統內的空氣
The first start or stop after a long time to start again,should use hand pressure pump first for exhausting the air in the fuel system
打開電開關,按起動按鈕或啟動電鎖,按下按鈕的時間3-5秒,若起動不成功后,應等待2分鐘左右,再作嘗試。若三次起動不成功,應停止起動,排除電瓶電壓或油路等故障因素后,再起動
Turn on the electric switch, press the start button or electric lock, press the button for 3 to 5 seconds。If the start unsuccessful you should be waited for about 2 minutes, try again.If the starting is not successful affter three times, stop the starting and start again excluding out battery voltage or circuits failure factors.
起動時應觀察機油壓力,若油壓無顯示或很低時,應立即停機檢查
When starting the engine oil pressure should be observed, if the oil pressure showed no or very low, should stop checking immediately.
機組起動后,檢查控制箱模塊或儀表各項參數:機油壓力、水溫、電壓、頻率等。
Generator starting, check control box module or instrument parameters: oil pressure, water temperature, voltage and frequency and so on .
一般情況,機組起動后轉速直接達到1500r/min,有怠速要求的機組,有刷發電機怠速的時間一般為3-5分鐘,無刷發電機怠速的時間為1分鐘左右,怠速時間不要過長,否則可能燒壞發電機組相關元器件。
In general, after starting the generator speed directly to 1500r / min. In accordance with the requirements of idle, brushless generator's idle time is usually 3-5 minutes, without brush generator's idle time for about 1 minute, idle time is not too long, otherwise it may burn the related components.
檢查機組油路、水路和氣路的滲漏情況,有無漏油、漏水和漏氣現象。
Check the Oil Channe, Canalage and Gas Path for leakage if there is leakage phenomenon of oil,water and gas.
注意機組各處的連接和堅固情況,有無松動和劇烈震動。
Pay attention to the connection and strong everywhere, with no loosening and severe vibration.
觀察機組各種保護和監視裝置是否正常。
Observe various generator protection and monitoring device is normal.
當轉速達到額定轉速,且空載運行各項參數穩定后,合閘向負載供電。
When the speed reach the rated speed,and after each parameter stable with no-load running,switching power supply to the load
檢查確認控制屏各項參數在允許的范圍內,再次檢查機組的振動,有無三漏以及有無其他故障.
Check the control panel parameters in the allowed range, check again the vibration of the generating set, without leakage of oil water and gas, and any other malfunction.
Need specialist attendant when the generator operation, overload is strictly prohibited!
停機前必須先分閘,一般情況卸載機組需運轉3~5分鐘后停機
Must first be break-brake before downtime. usually uninstall generator set after 3 ~ 5 minutes running.
發電機組運轉出現異常情況時,必須立即停機
When the operation of generator set is abnormal, must stop immediately
緊急停機時,按下急停按鈕或將噴油泵停機控制手柄迅速地推到停車位置
In an emergency, press the emergency stop button or push the control handlethe of fuel injection pump downtime to the stop position quickly .
柴油濾芯更換時間為每300小時左右;空氣濾芯更換時間為每400小時左右;機油濾芯次更換時間 為50小時,以后為250小時左右。
Diesel filter replacement time is 300 hours; air filter replacement time is 400 hours; the first engine oil filter replacement time is 50 hours, then every 250 hours to replace.
機油次更換時間為50小時,機油正常更換時間為每250小時左右,推薦的機油粘度級別(粘度等級SAE)為15W-40;質量級別(性能等級API,美國石油協會的機油性能分類)詳見柴油機說明書及隨同資料的要求.注意:粘度級別和質量級別都要符合要求。例如:15W/40CF-4,粘度級別:15W-40質量級別:CF-4。
First time to replace the engine oil after 50 hours,engine oil normal replacement time is about pre 250 hour.Engine oil viscosity level recommended (viscosity SAE grade) is 15w-40;The quality level (Performance Level,API the oil performance classification of American Petroleum Institute) is required to diesel engine specifications and informations.Note: the viscosity grade and quality level to meet the requirements. For example: 15W/40CF-4 viscosity grade: 15W-40 quality level: CF-4.
當打開控制屏時,必須采取必要的防護措施,以防可能發生的觸電事故。
When you open the control panel, must take the necessary protective measures to prevent electric shock accidents occured.
不允許隨意更改發電機組電路和控制器參數,由此造成的損失和售后服務費用由客戶承擔。
Not allowed to change the parameters of generator circuit and the controller, the loss and after-sale service fee payed by the customer.
江蘇雙馬機電有限公司是柴油發電機廠家、發電機組廠家,專業生產康明斯、沃爾沃、玉柴等柴油發電機組,發電機廠家歡迎前來選購。